Free Utah electrician tool

Watts to amps calculator, with a breaker check built in

Type what you know, like "1500 watts" or "50 amps at 240". Get amps, watts, kW, the math and the breaker size the load needs.

1,500 W at 120 V = 12.5 A

Volts
A digital multimeter whose screen shows the live result of the watts to amps calculator, with test leads running to a wall outlet AC 1φ · 120 V · PF 1.00 12.5 AMPS AWkWkVAHP ELITE
  1. 1Type watts, amps, kW or HP
  2. 2Pick the voltage and circuit type
  3. 3See amps and the breaker you need
The quick answer

How do you convert watts to amps?

Divide watts by volts. A 1,500-watt heater on a 120-volt outlet draws 1,500 ÷ 120 = 12.5 amps. For AC motors and electronics, also divide by the power factor; for 3-phase, divide by 1.732 too. Utah homes have 120 V and 240 V circuits, and the same load draws half the amps at 240 V. This watts to amps calculator also flags the breaker size: loads running 3+ hours stay under 80% of it.

DCA = W ÷ V
AC single-phaseA = W ÷ (V × PF)
AC 3-phaseA = W ÷ (1.732 × V × PF)

Elite Electric Pro · Licensed Utah electrical contractor · Sandy, UT · Checked Nov 28, 2026

Breaker panel opened for a watts to amps load check by Elite Electric in Utah
Every breaker has an amp limit. The math tells you how close you are.
Converter

Amps to watts, kW to amps and more in one converter

Start from your situation or set each value yourself.

Unit
Circuit type
Use line-to-line volts for 3-phase.
Power factor

EV charging, heaters and pumps count. Keep them under 80% of the breaker.

12.5amps

1,500 W on a 120 V single-phase circuit

20AMP

0%

0%80%100%

Breaker sizes

How many watts can a 15, 20, 30 or 50 amp circuit handle?

Pick a breaker to see its full limit, its 80% limit and which appliances fit.

15 A at 120 V
1,800 W

1,440 Wfor loads that run 3+ hours
12 Acontinuous amp limit
    Watts each breaker size can handle
    BreakerCircuitFull limit80% continuous
    15 A120 V1,800 W1,440 W
    20 A120 V2,400 W1,920 W
    30 A240 V7,200 W5,760 W
    40 A240 V9,600 W7,680 W
    50 A240 V12,000 W9,600 W
    60 A240 V14,400 W11,520 W
    Appliance explorer

    How many amps does it use? Typical appliance watts and amps

    Typical wattages from the U.S. Department of Energy. Your appliance's label wins.

    • Coffee maker

      900–1,200 W · 120 V

      up to 10.0 A

      67%
    • Microwave

      750–1,100 W · 120 V

      up to 9.2 A

      61%
    • Toaster

      800–1,400 W · 120 V

      up to 11.7 A

      78%
    • Dishwasher

      1,200–2,400 W · 120 V

      up to 20.0 A

      133%
    • Refrigerator, 16 cu ft

      725 W · 120 V

      up to 6.0 A

      40%
    • Clothes washer

      350–500 W · 120 V

      up to 4.2 A

      28%
    • Electric clothes dryer

      1,800–5,000 W · 240 V

      up to 20.8 A

      Needs 30 A circuit
      Own circuit
    • Clothes iron

      1,000–1,800 W · 120 V

      up to 15.0 A

      100%
    • Portable heater

      750–1,500 W · 120 V

      up to 12.5 A

      83%
    • Dehumidifier

      785 W · 120 V

      up to 6.5 A

      44%
    • Hair dryer

      1,200–1,875 W · 120 V

      up to 15.6 A

      104%
    • Water heater, 40 gal

      4,500–5,500 W · 240 V

      up to 22.9 A

      Needs 30 A circuit
      Own circuit
    • Desktop computer

      120 W · 120 V

      up to 1.0 A

      7%
    • Flat-screen TV

      120 W · 120 V

      up to 1.0 A

      7%
    • Vacuum cleaner

      1,000–1,440 W · 120 V

      up to 12.0 A

      80%
    • Deep-well pump

      250–1,100 W · 240 V

      up to 4.6 A

      Needs 15 A circuit
      Own circuit
    • EV charger at 32 A

      7,600 W · 240 V

      up to 31.7 A

      Needs 40 A circuit
      Own circuit
    • EV charger at 48 A

      11,500 W · 240 V

      up to 47.9 A

      Needs 60 A circuit
      Own circuit

    Source: typical wattages from the U.S. Department of Energy appliance list, published by Virginia Cooperative Extension. EV charger figures from Tesla's Wall Connector breaker table. Amps use the high end.

    Circuit stacker

    Will these trip my breaker? Add up one circuit

    Tap "+ Stack" on any 120 V appliance above, or try a common combo.

      Nothing on this circuit yet.

      Breaker on this circuit

      Bedrooms are often 15 A. Kitchens and bathrooms use 20 A.

      Circuit load gauge from 0 to 120 percent of the breaker 0 A of 15 A

      Add an appliance

      We'll show whether this breaker holds, and for how long.

      Equipment in amps

      kW to amps for EV chargers, batteries and generators

      What popular Utah home equipment pulls at 240 V, from each maker's spec sheet.

      Tesla Wall Connector

      48 A

      11.5 kW on a 60 A breaker, or 7.6 kW set to 32 A.

      Tesla Powerwall 3

      48 A

      11.5 kW continuous output, 13.5 kWh stored.

      Enphase IQ Battery 5P

      16 A

      3.84 kW continuous, 5 kWh per battery.

      Sigenergy SigenStor

      48 A

      The 11.5 kW energy controller size.

      Generac 26 kW standby

      108 A

      26,000 W on propane, 22,500 W on natural gas (about 94 A).

      Powerwall 3 · IQ Battery 5P · SigenStor 11.5 · Generac 26 kW. Amps = watts ÷ 240 V. Compare backup options on the battery vs generator simulator.

      Cheat sheet

      Watts to amps chart at 120 V, 240 V and 12 V

      For heaters, lights and other loads at power factor 1.

      Watts to amps at 120 volts, 240 volts and 12 volts DC
      Watts120 V240 V12 V DC
      500 W4.17 A2.08 A41.7 A
      1,000 W8.33 A4.17 A83.3 A
      1,500 W12.5 A6.25 A125 A
      2,000 W16.7 A8.33 A166.7 A
      2,400 W20 A10 A200 A
      3,000 W25 A12.5 A250 A
      5,000 W41.7 A20.8 A416.7 A
      7,500 W62.5 A31.2 A625 A
      Elite Electric tip

      A tripping breaker is doing its job. Never swap in a bigger one. The wire sets the limit.

      Elite Electric tip

      One 1,500 W space heater uses 83% of a 15 A circuit. Add a vacuum and it trips.

      Elite Electric tip

      Adding an EV charger, hot tub or battery? Check your panel with the panel upgrade calculator.

      Hot tub control wiring on a dedicated 240 V circuit installed by Elite Electric
      Questions

      Watts, amps and breaker questions

      Need a circuit checked in Salt Lake, Utah or Davis County? Call (801) 928-7219.

      How many amps is 1500 watts?
      12.5 amps at 120 volts, or 6.25 amps at 240 volts. That's 83% of a 15 A breaker, over the 80% limit for long use.
      How many amps is 2000 watts at 240V?
      About 8.3 amps (2,000 ÷ 240). At 120 volts it's 16.7 amps, enough to fill a 20 A circuit.
      How many amps is 7500 watts at 120V?
      62.5 amps, more than any household 120 V circuit carries. At 240 V it's about 31 amps, on a 40 A breaker.
      How many watts can a 20 amp circuit handle?
      2,400 watts at 120 volts, or 1,920 watts for loads that run 3 hours or more. A 15 A circuit handles 1,800 watts, or 1,440 watts continuous.
      How do you convert amps to kW?
      Multiply amps by volts and the power factor, then divide by 1,000. 30 amps at 240 volts is 7.2 kW. For 3-phase, also multiply by 1.732.
      Talk to a licensed electrician

      Need a new circuit or more capacity? Elite wires it right in Utah

      Send your result and a licensed Utah electrician will check your panel, the wire size and the breaker, then give you a written price. Rebecca calls back within about one business day.

      Prefer to talk? (801) 928-7219 · Mon–Sat 9–5 · Sandy, UT

      CallGet a quote